AIM: The radiation exposure in radiation synovectomy was investigated for technician and therapist using Erbium-169, Rhenium-186 and Yttrium-90 with and without syringe shieldings. METHODS: Dose rates were measured in relation to the distance of the syringe containing the radionuclide...
Keywords: Spritzenabschirmung, Radiosynoviorthese, Strahlen-exposition, Betastrahler, Erbium-169, Rhenium-186, Yttrium-90
01/2003 | Nuklearmedizin, Schattauer