Science.Online
Publisher and Institutes
Akademie Verlag
Deutsches Institut für Urbanistik
Oldenbourg Wissenschaftsverlag
Walter de Gruyter
Schattauer
You are here: Home :: Area NEM :: Medical science :: Human medicine :: Nuclear medicine
 
M. Gotthardt, C. Rubner, A. Bauhofer, F. Berce, W. J. G. Oyen, J. Goecke, A. Pfestroff, A. Schlieck, F. H. Corstens, M. Bh, T. M. Behr

What is the best pre-therapeutic dosimetry for successful radioiodine therapy of multifocal autonomy?

Keywords: Radioiodine treatment, thyroid, dosimetry, endocrinology,

PURPOSE: Dose calculation for radioiodine therapy (RIT) of multifocal autonomies (MFA) is a problem as therapeutic outcome may be worse than in other kinds of autonomies. We compared different dosimetric concepts in our patients. PATIENTS, METHODS: Data from 187 patients who had undergone RIT for MFA (Marinelli algorithm, volumetric compromise) were included in the study. For calculation, either a standard or a measured half-life had been used and the dosimetric compromise (150 Gy, total thyroid volume). Therapeutic activities were calculated by 2 alternative concepts and compared to therapeutic success achieved (concept of TcTUs-based calculation of autonomous volume with 300 Gy and TcTUs-based adaptation of target dose on total thyroid volume). RESULTS: If a standard half-life is used, therapeutic success was achieved in 90.2% (hypothyroidism 23,1%, n = 143). If a measured half-life was used the success rate was 93.1% (13,6% hypothyroidism, n = 44). These differences were statistically not significant, neither for all patients together nor for subgroups eu-, hypo-, or hyperthyroid after therapy (ANOVA, all p > 0.05). The alternative dosimetric concepts would have resulted either in significantly lower organ doses (TcTUs-based calculation of autonomous volume; 80.76 80.6 Gy versus 125.6 46.3 Gy; p < 0.0001) or in systematic over-treatment with significantly higher doses (TcTUs-adapted concept; 164.2 101.7 Gy versus 125.6 46.3 Gy; p = 0.0097). CONCLUSIONS: TcTUsbased determination of the autonomous volume should not be performed, the TcTUs-based adaptation of the target dose will only increase the rate of hypothyroidism. A standard half-life may be used in pre-therapeutic dosimetry for RIT of MFA. If so, individual therapeutic activities may be calculated based on thyroid size corrected to the 24h ITUs without using Marinelli's algorithm.

Nuklearmedizin, Schattauer

Print ISSN: 0029-5566
Volume: 45, 01/2006
Pages: 206 - 212

Show full article (external site)

Show all available items of this journal