Fionnuala Breathnach, Sean Daly, Elizabeth Griffin, Noreen Gleeson

Intracervical application of synthetic hydrogel sealant for preterm prelabor rupture of membranes: a case report

Keywords: Intracervical sealants, oligohydramnios, prelabor preterm rupture of membranes

We report a case of prelabor rupture of membranes at 20 weeks' gestation where a hydrogel sealant was applied to the cervical canal in order to maintain an adequate liquor volume in the second trimester. The use of this agent for the purpose of creating a cervical plug has not been reported to date.

Journal of Perinatal Medicine, Walter de Gruyter

Print ISSN: 1619-3997
Volume: 33, 10/2005
Pages: 458 - 460