Science.Online
Publisher and Institutes
Akademie Verlag
Deutsches Institut für Urbanistik
Oldenbourg Wissenschaftsverlag
Walter de Gruyter
Schattauer
You are here: Home :: Area NEM :: Medical science :: Human medicine
 
L. Siekmann, R. Bonora, C. A. Burtis, F. Ceriotti, P. Clerc-Renaud, G. Férard, C. A. Ferrero, J.-C. Forest, P. F. H. Franck, F.-J. Gella, W. Hoelzel, P. J. Jørgensen, T. Kanno, A. Kessner, R. Klauke, N. Kristiansen, J.-M. Lessinger, T. P. J. Linsinger, H.

IFCC Primary Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes at 37°C. Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of ?-Glutamyltransferase, Lactate Dehydrogenase, A

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37°C and the certification of reference preparations. Other parts deal with:

Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of ?-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation.

The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37°C of four enzyme preparations, namely IRMM/IFCC 452 ?-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37°C are 1.90 ?kat/l ± 0.04 ?kat/l (114.1 U/l ± 2.4 U/l), for ?-glutamyltransferase, 8.37 ?kat/l ± 0.12 ?kat/l (502 U/l ± 7 U/l), for lactate dehydrogenase 1, 3.09 ?kat/l ± 0.07 ?kat/l (186 U/l ± 4 U/l), for alanine aminotransferase and 1.68 ?kat/l ± 0.07 ?kat/l (101 U/l ± 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.

Clinical Chemical Laboratory Medicine, Walter de Gruyter

Print ISSN: 1434-6621
Volume: 40, 07/2002
Pages: 739 - 745

Show full article (external site)

Show all available items of this journal