A. Kurjak, S. Kupesic, M. Ivan?i?-Ko?uta

Three-dimensional transvaginal ultrasound improves measurement of nuchal translucency

The aim of the study was to correlate intra-observer reproducibility of the nuchal translucency measurements by two-dimensional and three-dimensional transvaginal ultrasound. Examinations were performed on 120 women undergoing ultrasound screening at 10 to 14 weeks' gestation. They were examined by two experienced ultrasonographers using both methods two times consecutively. Statistical analysis for the assessment of intra-observer reproducibility was paired t-test.

Nuchal translucency measurements were obtained in 100 % of cases with three-dimensional sonography compared to only 85 % with two-dimensional sonography. Better intra-observer reproducibility was obtained for three-dimensional than for two-dimensional ultrasound.

Three-dimensional transvaginal ultrasound improves accuracy of nuchal translucency measurement allowing appropriate mid-sagittal section of the fetus and clear distinction of the nuchal region from the amniotic membrane.

Journal of Perinatal Medicine, Walter de Gruyter

Print ISSN: 1619-3997
Volume: 27, 04/1999
Pages: 97 - 102

Show full article (external site)

Show all available items of this journal