Lucio Marchioro, Flavia Bassetto, Giuliano Dall'Olio, Luciano Tedeschi, Franca Castagna, Mario Plebani

Amphetamines and 3,4-methylendioxymetamphetamine (MDMA): evaluation of KIMS (kinetic interaction of microparticles in solution) assay at two cut-off levels

Two screening methods for the assay of amphetamines and their derivatives have been applied to the same analytical instrument for their evaluation. In addition to an assay at a cut-off of 1000 ?g/l, a new specific reagent was evaluated for an ultra-sensitive assay of amphetamines and 3,4-methylendioxyme-tamphetamine with a cut-off of 300 ?g/l. The assay confirmation was performed using high-performance liquid chromatography and gas chromatography/mass spectrometry techniques. The results were positive for both screening methods, confirming the efficacy of two simultaneous methods with different cut-off levels.

Clinical Chemical Laboratory Medicine, Walter de Gruyter

Print ISSN: 1434-6621
Volume: 42, 05/2004
Pages: 543 - 548

Show full article (external site)